Inkcazelo emfutshane:

I-Pulse Oximeter iyisixhobo esibalulekileyo kunye nesiqhelekileyo ukujonga i-oxygen saturation (SpO2) kunye nesantya se-pulse.Sisixhobo esincinci, esincinci, esilula, esithembekileyo kwaye esihlala sihleli.Faka ibhodi ephambili, umboniso kunye neebhetri ezomileyo.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Ingcaciso yeMveliso
I-Pulse Oximeter iyisixhobo esibalulekileyo kunye nesiqhelekileyo ukujonga i-oxygen saturation (SpO2) kunye nesantya se-pulse.Sisixhobo esincinci, esincinci, esilula, esithembekileyo kwaye esihlala sihleli.Faka ibhodi ephambili, umboniso kunye neebhetri ezomileyo.

Ukusetyenziswa okucetywayo
I-pulse oximeter sisixhobo esiphinda sisetyenziswe kwaye sisetyenziselwa ukujonga indawo ye-pulse oxygen saturation kunye ne-pulse rate kumntu omdala.Esi sixhobo sonyango sinokuphinda sisetyenziswe.Ayiyiyo eyokubeka iliso rhoqo.

Abantu abasebenzayo kunye nobubanzi
I-pulse oximeter yenzelwe ukubeka iliso kubantu abadala.Musa ukusebenzisa esi sixhobo ukuxilongwa okanye ukunyanga nayiphi na ingxaki yezempilo okanye isifo.Iziphumo zomlinganiselo zezentengiselwano kuphela,bonana nochwepheshe bezempilo ukuze batolike iziphumo ezingaqhelekanga.

Contraindications
Imveliso isebenza kuphela kubantu abadala.Nceda ungayisebenzisi imveliso kubantwana, usana kunye nosana olusanda kuzalwa.
Ulusu olonakeleyo alunakulinganiswa.

Umgaqo-siseko womlinganiselo
Umgaqo wokusebenza usekelwe ekuhanjisweni kokukhanya nge-hemoglobin.Ukuhanjiswa kokukhanya kwento kumiselwa ngumthetho we-Beer-Lambert, omisela ukuxinana kwe-solute (oxyhemoglobin) kwi-solvent (i-hemoglobin) inokumiselwa ngokufunxa ukukhanya.Ibala legazi lixhomekeke kumanqanaba e-oksijini yegazi, kunye negazi eline-oxygen ephezulu
Ugxininiso lubonisa umbala obomvu ngenxa yokuxinana okuphezulu kwe-oxyhemoglobin.Xa ugxininiso luncitshisiwe, igazi lithatha i-bluish ngakumbi, ngenxa yobukho obukhulu be-deoxyhemoglobin (ukuhlanganiswa kweemolekyuli ze-hemoglobin kunye ne-carbon dioxide).Oko kukuthi, igazi lisekelwe kwi-spectrophotometry, ukulinganisa umlinganiselo wokukhanya ohanjiswe ngee-capillaries zesigulane, ehambelana ne-pulse yentliziyo.
1. I-Infrared Light Emitting
2. I-infrared Light receiver

Ulwazi ngoKhuseleko
Umntu osebenzisa i-pulse oximeter kufuneka afumane uqeqesho olwaneleyo ngaphambi kokusetyenziswa.
I-pulse oximeter ijoliswe kuphela njenge-adjunct kuvavanyo lwesigulane.Kufuneka isetyenziswe ngokubambisana neempawu zeklinikhi kunye neempawu.Ayenzelwanga njengesixhobo esisetyenziselwa iinjongo zonyango.
Xa usebenzisa i-pulse oximeter kunye nesixhobo sotyando lombane, umsebenzisi kufuneka anikele ingqalelo kwaye aqinisekise ukhuseleko lwesigulane esilinganiswayo.
INGOZI YODUNDUKO: Musa ukusebenzisa i-pulse oximeter xa kukho izibulali-ntlungu ezinokutsha, izinto eziqhushumbayo, umphunga okanye ulwelo.
Qinisekisa ukuba awusebenzisi i-pulse oximeter ngexesha le-MRI (imagnetic resonance imaging) yokuskena okanye i-CT (Computed Tomography) imekobume kuba i-induced current inokubangela ukutshisa.
I-pulse oximeter ayinamsebenzi we-alamu.Ukubeka iliso okuqhubekayo ixesha elide akufanelekanga.
Akukho kuguqulwa kwemveliso kuvunyelwe.Ugcino kufuneka luqhutywe ngabasebenzi abaqeqeshiweyo bolondolozo abavunywe ngabavelisi.
Nceda ucime umbane ngaphambi kokuba ucoce i-pulse oximeter.Ungaze uvumele ukubulawa kweentsholongwane kuxinzelelo oluphezulu kunye nobushushu obuphezulu besixhobo.Ungaze usebenzise izinto zokucoca/izibulali ntsholongwane ngaphandle kokucetyiswayo.
Imveliso idla ngokutywinwa.Gcina umphezulu wayo womile kwaye ucocekile, kwaye uthintele naluphi na ulwelo ekungeneni kulo.
I-pulse oximeter ichanekile kwaye ibuthathaka.Gwema uxinzelelo, ukunkqonkqoza, ukungcangcazela okunamandla okanye omnye umonakalo owenziwe ngoomatshini.Yibambe ngononophelo kwaye kancinci.Ukuba ayisetyenziswa, kufuneka ibekwe ngokufanelekileyo.
Ukulahla i-pulse oximeter kunye nezincedisi, landela imimiselo yasekuhlaleni okanye umgaqo-nkqubo wesibhedlele sakho malunga nokulahlwa kwe-pulse oximeter kunye nezincedisi.Musa ukulahla ngokungenamkhethe.
Sebenzisa iibhetri ze-alkaline ze-AAA.Musa ukusebenzisa ikhabhoni okanye iibhetri ezikumgangatho ophantsi.Susa iibhetri ukuba imveliso ayifanele isetyenziswe ixesha elide.
Umvavanyi osebenzayo akanakusetyenziswa ukuhlola ukuchaneka.
Ukuba ngaba isigulana singumsebenzisi ocetyiweyo, kufuneka ufunde incwadi yotyando ngononophelo kwaye uqonde nzulu okanye udibane nogqirha kunye nomvelisi phambi kokuba uyisebenzise.Ukuba kukho nakuphi na ukungonwabi ekusebenziseni, nceda uyeke ukusebenzisa kwangoko kwaye uye esibhedlele.
Gwema umbane osisigxina, ngaphambi kokusebenzisa i-pulse oximeter, umbane ochanekileyo othe ngqo okanye ongathanga ngqo kubo bonke abaqhubi kunye nezigulane eziqhagamshelana nesixhobo.
Xa isetyenziswa, zama ukwenza i-pulse oximeter ingabi kude kumamkeli werediyo.
Ukuba i-pulse oximeter isebenzisa engachazwanga kwaye ngaphandle kohlengahlengiso lwenkqubo yovavanyo lwe-EMC, inokuphucula imitha ye-electromagnetic okanye inciphise uphazamiseko oluchasene nombane.Nceda usebenzise ubumbeko olukhankanyiweyo.
Izixhobo zonxibelelwano zerediyo eziphathwayo nezihambayo zinokuchaphazela ukusetyenziswa okuqhelekileyo kwe-pulse oximeter.
I-pulse oximeter akufuneki isondele okanye ipakishwe kunye nezinye izixhobo, ukuba kufuneka ube kufutshane okanye uzipakishe xa zisetyenziswa, kufuneka uyiqwalasele kwaye uqinisekise ukuba inokuhamba ngesiqhelo kunye noqwalaselo olulusebenzisayo.  Kufuneka iqinisekise ukuba kukho akukho bumdaka okanye inxeba kwindawo evavanyiweyo.
Ukuba imveliso ihloselwe ukuvumela ukuxilongwa ngokuthe ngqo okanye ukubeka iliso kwiinkqubo ezibalulekileyo ze-physiological, ngoko kunokwenzeka ukuba kubangele ingozi ngokukhawuleza kwisigulane.
Nceda ugcine le oximeter kunye nezixhobo zayo kwindawo ekhuselekileyo ukuthintela ukulunywa kwezilwanyana zasekhaya ukuba zingaphuki okanye izinambuzane zingangeni.Gcina ii-oximeters kunye neenxalenye ezincinci ezifana neebhetri ngaphandle kokufikelela kubantwana ukuphepha iingozi.
Abantu abakhubazekileyo ngengqondo kufuneka basetyenziswe phantsi kweliso labantu abadala abaqhelekileyo ukuthintela ukukrwitshwa ngenxa yeLanyard.
Qhagamshela isincedisi ngononophelo ukunqanda ukuba isigulana sisontwe okanye sikrwitshwe.

Uphawu lweMveliso
Ukusetyenziswa okulula kunye nokufanelekileyo kwemveliso, umsebenzi olula wokuchukumisa omnye.
Umthamo omncinci, ubunzima obulula, obulungele ukuthwala.
Ukusetyenziswa okuphantsi, iibhetri ezimbini ze-AAA zoqobo zinokusebenza ngokuqhubekayo iiyure ezili-15.
Isikhumbuzi sombane osezantsi siboniswa kwiscreen xa ibhetri iphantsi.
Umatshini uya kuzicima ngokuzenzekelayo emva kwemizuzwana eyi-10 xa kungekho mqondiso uveliswayo.

Bonisa Intshayelelo

hfd (3)
Umfanekiso woku-1

Amanyathelo okulinganisa
1. Bamba imveliso kwisandla esinye kunye nepaneli yangaphambili ejongene nesundu.Beka umnwe omkhulu wesinye isandla kwikhava yebhetri, susa isiciko sebhetri kwicala lotolo (njengoko kubonisiwe kuMfanekiso 2).

2. Faka iibhetri kwiindawo zokubeka ngokwesimboli "+" kunye no "-" njengoko kubonisiwe kuMfanekiso 3. Gquma isiciko kwikhabhathi kwaye uyityhale phezulu ukuze ivale kakuhle.

3.Cinizela amandla kunye neqhosha lokutshintsha umsebenzi kwipaneli yangaphambili ukuze uvule imveliso.Ukusebenzisa umnwe wokuqala, umnwe ophakathi okanye umnwe weringi xa usenza uvavanyo.Musa shank umnwe kwaye ugcine testee kwimeko ngexesha lenkqubo.Ufundo luya kuboniswa kwiscreen umzuzwana emva koko njengoko kubonisiwe kuMfanekiso 4.

I-electrodes efanelekileyo kunye ne-negative yeebhetri kufuneka ifakwe ngokuchanekileyo.
Kungenjalo isixhobo siya konakaliswa.
Xa ufaka okanye ususa iibhetri, nceda ulandele ulandelelwano oluchanekileyo lokusebenza ukuze usebenze.Kungenjalo indawo yebhetri iya konakaliswa.
Ukuba i-pulse oximeter ayisetyenziswanga ixesha elide, nceda ususe iibhetri zayo.
Qinisekisa ukuba ubeke imveliso emnweni ngendlela echanekileyo.Inxalenye ye-LED ye-sensor kufuneka ibe ngasemva kwesandla sesigulane kunye nenxalenye ye-photodetector ngaphakathi.Qinisekisa ukuba ufaka umnwe kubunzulu obufanelekileyo kwisixhobo soluvo ukuze uzipho luchasane nokukhanya okuphuma kwisivamvo.
Musa ukushukumisa umnwe kwaye ugcine testee ezolile ngexesha lenkqubo.
Ixesha lohlaziyo lwedatha lingaphantsi kwemizuzwana engama-30.

hfd (4)
hfd (5)
Umzobo 4

PHAWULA:
Ngaphambi kokulinganisa, i-pulse oximeter kufuneka ihlolwe ukuba iyinto eqhelekileyo, ukuba yonakele, nceda ungasebenzisi.
Musa ukufaka i-pulse oximeter kwiziphelo nge-catheter ye-arterial okanye isirinji ye-venous.
Musa ukwenza esweni i-SpO2 kunye nemilinganiselo ye-NIBP kwingalo enye
ngaxeshanye.Ukuthintela ukuhamba kwegazi ngexesha lemilinganiselo ye-NIBP kunokuchaphazela kakubi ukufundwa kwexabiso le-SpO2.
Musa ukusebenzisa i-pulse oximeter ukulinganisa izigulane ezinezinga le-pulse elingaphantsi kwe-30bpm, ezinokubangela iziphumo ezingalunganga.
Inxalenye yokulinganisa kufuneka ikhethwe kakuhle i-perfusion kwaye ikwazi ukugubungela ngokupheleleyo ifestile yokuvavanya yenzwa.Nceda ucoce indawo yokulinganisa ngaphambi kokubeka i-pulse oximeter, kwaye uqinisekise ukomisa.
Gubungela inzwa ngempahla ye-opaque phantsi kwemeko yokukhanya okunamandla.Ukungaphumeleli ukwenza oko kuya kubangela umlinganiselo ongachanekanga.
Qinisekisa ukuba akukho ngcoliseko kunye nesiva kwindawo evavanyiweyo.Ngaphandle koko, isiphumo esilinganisiweyo sinokungalunganga kuba isibonakaliso esifunyenwe yinzwa sichaphazelekayo.
Xa isetyenziswe kwizigulane ezahlukeneyo, imveliso ixhomekeke kwi-contamination enqamlezileyo, ekufuneka ikhuselwe kwaye ilawulwe ngumsebenzisi.Ukubulala iintsholongwane kuyacetyiswa phambi kokuba usebenzise imveliso kwezinye izigulana.
Ukubekwa okungafanelekanga kwenzwa kunokuchaphazela ukuchaneka komlinganiselo, kwaye ikwindawo efanayo ethe tye nentliziyo, umphumo wokulinganisa ungcono.
Elona qondo lobushushu liphezulu loqhagamshelwano lwenzwa nolusu lwesigulana aluvunyelwa ngaphezulu kwe-41℃.
Ukusetyenziswa ixesha elide okanye imeko yesigulane inokufuna ukutshintsha indawo yenzwa ngamaxesha athile.Guqula indawo yesivamvo kwaye ujonge ingqibelelo yolusu, ubume bokujikeleza, kunye nokulungelelaniswa okuchanekileyo ubuncinci neeyure ze-2.

Izinto ezichaphazela ukuchaneka komlinganiselo:
Imilinganiselo ikwaxhomekeke ekufunxeni imitha yobude obukhethekileyo nge-hemoglobin ene-oxidized kunye ne-deoxyhemoglobin.Ukugxilwa kwe-hemoglobin engasebenziyo kunokuchaphazela ukuchaneka komlinganiselo.
Ukothuka, i-anemia, i-hypothermia kunye nokusetyenziswa kweyeza le-vasoconstriction kunokunciphisa ukuhamba kwegazi kwi-arteria ukuya kwinqanaba elingenakulinganiswa.
Ibala lebala, okanye umbala onzulu (umzekelo: ipolishi yeenzipho, iinzipho ezenziweyo, idayi okanye ikhrimu enemibala) inokubangela imilinganiselo engachanekanga.

Inkcazo yomsebenzi

a.Xa idatha ibonisiwe kwisikrini, cofa ngokufutshane iqhosha elithi "MANDLA/FUNCTION".
ngexesha elinye, isalathiso somboniso siya kujikeleziswa.(njengoko kubonisiwe kuMfanekiso 5,6)
b.Xa isignali efunyenweyo ingoneli, iya kuboniswa kwisikrini.
c.Imveliso iya kucinywa ngokuzenzekelayo xa kungekho mqondiso emva kwemizuzwana ye-10.

hfd (6)

Umfanekiso wesi-5

Umfanekiso wesi-6

Ukuxhoma intambo yentambo
1. Faka umsonto obhityileyo weleyisi ejingayo kumngxunya ojingayo.
2. Yenza umsonto ongqindilili weleyisi kwincam ephothiweyo phambi kokuba uyitsale ngokuqinileyo.

Ukucoca kunye nokubulala iintsholongwane
Ungaze ucwilise okanye ucwilise i-pulse oximeter.
Sincoma ukucoca kunye ne-disinfecting imveliso xa kuyimfuneko okanye xa isetyenziswe kwizigulane ezahlukeneyo ukuphepha umonakalo kwimveliso.
Ungaze usebenzise izinto zokucoca/izibulali ntsholongwane ngaphandle kokucetyiswayo.
Ungaze uvumele ukubulawa kweentsholongwane kuxinzelelo oluphezulu kunye nobushushu obuphezulu besixhobo.
Nceda ucime umbane kwaye ukhuphe iibhetri phambi kokucoca kunye nokubulala iintsholongwane.

Ukucoca
1. Coca imveliso ngomqhaphu okanye ilaphu elithambileyo elimanziswe ngamanzi.2.Emva kokucoca, sula amanzi ngelaphu elithambileyo.
3. Vumela imveliso ukuba yome emoyeni.

Ukubulala iintsholongwane
I-disinfectants ecetyiswayo iquka: i-ethanol 70%, isopropanol 70%, i-glutaraldehyde (2%).
isisombululo sokubulala iintsholongwane.
1. Coca imveliso njengoko kuyalelwe ngasentla.
2. Ukubulala iintsholongwane kwimveliso ngomqhaphu okanye ilaphu elithambileyo elifakelwe enye yeentsholongwane ezicetyiswayo.
3. Emva kwe-disinfection, qiniseka ukuba usule isibulala-ntsholongwane esishiywe kwimveliso ngelaphu elithambileyo elixutywe ngamanzi.
4. Vumela imveliso ukuba yome emoyeni.

Uluhlu lokupakisha
Ubomi benkonzo obulindelekileyo: iminyaka emi-3

hfd (7)

IiNgcaciso zobuGcisa
1. Imowudi yokubonisa: Idijithali
2. SpO2:
Uluhlu lomlinganiselo: 35 ~ 100%
Ukuchaneka: ±2%(80%~100%);±3%(70%~79%)
3. Isantya sokutyhaphaza:
Uluhlu lokulinganisa: 25 ~ 250bpm
Ukuchaneka: ± 2bpm
Ukuchaneka kwe-Pulse Rate kudlule ubungqina kunye nokuthelekisa kunye ne-SpO2 simulator.
4. Iinkcukacha zombane:
Umbane osebenzayo: DC2.2 V~DC3.4V
Uhlobo lwebhetri: Iibhetri ezimbini ze-alkaline ze-1.5V AAA
Ukusetyenziswa kwamandla: kuncinci kune-50mA
5. Iinkcukacha zemveliso:
Ubungakanani: 58 (H) × 34 (W) × 30 (D) mm
Ubunzima: 50g (zibandakanya iibhetri ezimbini ze-AAA)
6. Iimfuno zokusingqongileyo:
PHAWULA:
Xa ubushushu bokusingqongileyo bungama-20℃, ixesha elifunekayo kwiPulse Oximeter ukuya
ukufudumala ukusuka kubushushu obuncinane bogcino phakathi kokusetyenziswa de ilungele
ukusetyenziswa okujoliswe kuyo yi-30 ukuya kwimizuzu engama-60.
Xa ubushushu bemo engqongileyo bungama-20℃, ixesha elifunekayo kwiPulse Oximeter tocool ukusuka kubushushu obuphezulu bokugcina phakathi kokusetyenziswa de ilungele ukusetyenziswa yimizuzu engama-30 ukuya kuma-60.
Ubushushu:
Ukusebenza: +5~+40℃
Ezothutho kunye nokugcinwa: -10 ~ + 50 ℃
Ukufuma:
Ukusebenza: 15% ~ 80% (
ukunganciphisi)
Ezothutho kunye nokugcinwa: 10% ~ 90% (
ukunganciphisi)
Uxinzelelo lomoya:
Ukusebenza: 860hPa ~ 1060hPa
Ukuthutha kunye nokugcinwa: 700hPa ~ 1060hPa
PHAWULA:
Umvavanyi osebenzayo akanakusetyenziswa ukuhlola ukuchaneka.
Indlela yokuqinisekisa ukuchaneka komlinganiselo weoksijini yegazi kukuthelekisa
ixabiso lokulinganisa i-oximetry ngexabiso le-analyzer yegesi yegazi.
Ukulungisa ingxaki

hfd (8)

Intsingiselo yoMqondiso

hfd (9)


  • Ngaphambili:
  • Okulandelayo: